{"id":4393,"date":"2024-02-03T05:18:17","date_gmt":"2024-02-03T04:18:17","guid":{"rendered":"https:\/\/openbim-knowledgebase.org\/docs\/chapter-2-basic-knowledge\/"},"modified":"2025-03-15T14:11:47","modified_gmt":"2025-03-15T13:11:47","password":"","slug":"chapter-2-basic-knowledge","status":"publish","type":"docs","link":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/docs\/bimcert-manual-2024\/chapter-2-basic-knowledge\/","title":{"rendered":"Chapter 2 &#8211; Basic knowledge"},"content":{"rendered":"\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">This chapter provides the basics for all those who want to prepare for the buildingSMART International &#8220;Professional Certification &#8211; Foundation&#8221;. It provides an easy introduction to the topic of <em>openBIM<\/em>. All basic terms for <em>openBIM <\/em>are explained here. All those involved in an <em>openBIM project<\/em> can therefore use a common language with the same terminology. This chapter thus provides the basis for <a href=\"https:\/\/staging-testing.openbim-knowledgebase.org\/docs\/bimcert-lehrbuch-2024\/kapitel-3-vertiefendes-wissen\/\" data-id=\"1793\" data-type=\"docs\">Chapter 3<\/a> and <a href=\"https:\/\/staging-testing.openbim-knowledgebase.org\/docs\/bimcert-lehrbuch-2024\/kapitel-4-bim-projektdurchfuehrung\/\" data-id=\"1794\" data-type=\"docs\">Chapter 4<\/a>, which deal with topics for practical implementation. The knowledge imparted in the following chapters also supports the preparation for the buildingSMART &#8220;Professional Certification &#8211; Practitioner&#8221; exam<em>(openBIM <\/em>Management and <em>openBIM<\/em> Coordination).     <br\/><br\/>Important abbreviations are:<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">ADD<\/td><td class=\"has-text-align-left\" data-align=\"left\">Addendum<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">AG<\/td><td class=\"has-text-align-left\" data-align=\"left\">Client<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">AIA<\/td><td class=\"has-text-align-left\" data-align=\"left\">Exchange information requirements (International: EIR)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">AIM<\/td><td class=\"has-text-align-left\" data-align=\"left\">Asset Information Model<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">AIR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Asset Information Requirements<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">ON<\/td><td class=\"has-text-align-left\" data-align=\"left\">Contractor<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">AR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Architecture<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">ASI<\/td><td class=\"has-text-align-left\" data-align=\"left\">Austrian Standards International<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">BAP<\/td><td class=\"has-text-align-left\" data-align=\"left\">BIM execution plan (International: BEP)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">BCF<\/td><td class=\"has-text-align-left\" data-align=\"left\">BIM Collaboration Format<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">BEP<\/td><td class=\"has-text-align-left\" data-align=\"left\">BIM Execution Plan (BIM execution plan)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">BPMN<\/td><td class=\"has-text-align-left\" data-align=\"left\">Business Process Modeling and Notation<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">bSAT<\/td><td class=\"has-text-align-left\" data-align=\"left\">buildingSMART Austria<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">bSCH<\/td><td class=\"has-text-align-left\" data-align=\"left\">buildingSMART Switzerland<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">bSD<\/td><td class=\"has-text-align-left\" data-align=\"left\">buildingSMART Germany<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">bSDD<\/td><td class=\"has-text-align-left\" data-align=\"left\">buildingSMART Data Dictionary<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">bSI<\/td><td class=\"has-text-align-left\" data-align=\"left\">buildingSMART International<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">CAD<\/td><td class=\"has-text-align-left\" data-align=\"left\">Computer Aided Design<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">CDE<\/td><td class=\"has-text-align-left\" data-align=\"left\">Common Data Environment<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">CEN\/TC<\/td><td class=\"has-text-align-left\" data-align=\"left\">Comit\u00e9 Europ\u00e9en de Normalization<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">CV<\/td><td class=\"has-text-align-left\" data-align=\"left\">Coordination View<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">DIN<\/td><td class=\"has-text-align-left\" data-align=\"left\">German Institute for Standardization<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">DTV<\/td><td class=\"has-text-align-left\" data-align=\"left\">Design Transfer View<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">DWG<\/td><td class=\"has-text-align-left\" data-align=\"left\">Drawing (file extension)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">DXF<\/td><td class=\"has-text-align-left\" data-align=\"left\">Drawing Interchange File Format<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">EIR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Exchange Information Requirements<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">EN<\/td><td class=\"has-text-align-left\" data-align=\"left\">European Norm<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">FM<\/td><td class=\"has-text-align-left\" data-align=\"left\">Facility Management<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">GUID<\/td><td class=\"has-text-align-left\" data-align=\"left\">Globally Unique Identifier<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">IAI<\/td><td class=\"has-text-align-left\" data-align=\"left\">International Alliance for Interoperability (older: Industry Alliance for Interoperability)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">IDM<\/td><td class=\"has-text-align-left\" data-align=\"left\">Information Delivery Manual<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">IDS<\/td><td class=\"has-text-align-left\" data-align=\"left\">Information Delivery Specification<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">IFC<\/td><td class=\"has-text-align-left\" data-align=\"left\">Industry Foundation Classes<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">IFD<\/td><td class=\"has-text-align-left\" data-align=\"left\">International Framework for Dictionaries<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">ISO<\/td><td class=\"has-text-align-left\" data-align=\"left\">International Organization for Standardization<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">LOD<\/td><td class=\"has-text-align-left\" data-align=\"left\">Level of Development (obsolete)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">LOG<\/td><td class=\"has-text-align-left\" data-align=\"left\">Level of Geometry<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">LOI<\/td><td class=\"has-text-align-left\" data-align=\"left\">Level of Information<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">LOIN<\/td><td class=\"has-text-align-left\" data-align=\"left\">Level of Information Need<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MEP<\/td><td class=\"has-text-align-left\" data-align=\"left\">Mechanical, electrical, and plumbing (building services)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MVD<\/td><td class=\"has-text-align-left\" data-align=\"left\">Model View Definition<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">OIR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Organizational Information Requirements<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u00d6NORM<\/td><td class=\"has-text-align-left\" data-align=\"left\">Austrian standard<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PAS<\/td><td class=\"has-text-align-left\" data-align=\"left\">Publicly Available Specification<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PDF<\/td><td class=\"has-text-align-left\" data-align=\"left\">Portable Document Format<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PIM<\/td><td class=\"has-text-align-left\" data-align=\"left\">Project Information Model<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PIR<\/td><td class=\"has-text-align-left\" data-align=\"left\">Project Information Requirements<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Plague<\/td><td class=\"has-text-align-left\" data-align=\"left\">Property Set<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">QA<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quality Assurance<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">QC<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quality Control<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RV<\/td><td class=\"has-text-align-left\" data-align=\"left\">Reference View<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">SIA<\/td><td class=\"has-text-align-left\" data-align=\"left\">Swiss Society of Engineers and Architects<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">STEP<\/td><td class=\"has-text-align-left\" data-align=\"left\">Standard for Exchange of Product model data<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">TC<\/td><td class=\"has-text-align-left\" data-align=\"left\">Technical Corrigendum<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">TGA<\/td><td class=\"has-text-align-left\" data-align=\"left\">Technical building equipment<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">TWP<\/td><td class=\"has-text-align-left\" data-align=\"left\">Structural design<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">UCM<\/td><td class=\"has-text-align-left\" data-align=\"left\">Use Case Management<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">XML<\/td><td class=\"has-text-align-left\" data-align=\"left\">Extensible Markup Language<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div><\/div>\n\n<p class=\"has-theme-palette-7-background-color has-background wp-block-paragraph\">Publication from Eichler, C.C., Schranz, Ch., Krischmann, T., Urban, H., Hopferwieser, M., Fischer, S.: <em>BIMcertHandbuch- Grundlagenwissen openBIM<\/em>. Issue 2024. Mironde-Verlag, Niederfrohna, 2024. DOI: 10.34726\/5384<br\/>URL: https:\/\/repositum.tuwien.at\/bitstream\/20.500.12708\/192612\/3\/Eichler-2024-BIMcert <a rel=\"noreferrer noopener\" href=\"https:\/\/repositum.tuwien.at\/bitstream\/20.500.12708\/192612\/3\/Eichler-2024-BIMcert%20Handbuch%20Grundlagenwissen%20openBIM-vor.pdf\" target=\"_blank\">%20Handbuch%20basic-knowledge%20openBIM-vor.pdf<\/a><br\/>Status: 23.01.2024<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Chapter 2 &#8211; Basic knowledge: Basics for the buildingSMART International &#8220;Professional Certification &#8211; Foundation&#8221; and an easy introduction to openBIM.<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":4402,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"doc_category":[],"doc_tag":[101],"class_list":["post-4393","docs","type-docs","status-publish","hentry","doc_tag-lehrbuch"],"aioseo_notices":[],"year_month":"2026-06","word_count":236,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"display_name":"Christoph Eichler","author_link":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/author\/christoph-eichler\/"},"doc_category_info":[],"doc_tag_info":[{"term_name":"Lehrbuch","term_url":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/doc-tag\/lehrbuch\/"}],"taxonomy_info":{"doc_tag":[{"value":101,"label":"Lehrbuch"}]},"featured_image_src_large":false,"comment_info":0,"comment_count":0,"_links":{"self":[{"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/docs\/4393","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/comments?post=4393"}],"version-history":[{"count":1,"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/docs\/4393\/revisions"}],"predecessor-version":[{"id":4394,"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/docs\/4393\/revisions\/4394"}],"up":[{"embeddable":true,"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/docs\/4402"}],"next":[{"title":"Chapter 3 - In-depth knowledge","link":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/docs\/bimcert-manual-2024\/chapter-3-in-depth-knowledge\/","href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/docs\/4391"}],"prev":[{"title":"Chapter 1 - Introduction: openBIM and buildingSMART","link":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/docs\/bimcert-manual-2024\/chapter-1-introduction-openbim-and-buildingsmart\/","href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/docs\/4395"}],"wp:attachment":[{"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/media?parent=4393"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/doc_category?post=4393"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/staging-testing.openbim-knowledgebase.org\/en\/wp-json\/wp\/v2\/doc_tag?post=4393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}